The base nickel-iron-chromium grade of the 800 family, used where oxidation and carburisation resistance matter more than creep strength.

Composition

Chemical composition limits, per cent by weight
ElementMinMax
Ni 30.0 35.0
Cr 19.0 23.0
Fe 39.5
Al 0.15 0.60
Ti 0.15 0.60
C 0.10
Mn 1.5

Per cent by weight, to the governing standard.

Nominal composition
  • Fe46.5
  • Ni32.5
  • Cr21.0

Per cent by weight, at the midpoint of each specified window. Elements given only as a maximum have no midpoint to take, so they sit inside the balance rather than being estimated; trace elements below 0.5 % are not shown. Indicative only; the composition table above and the governing standard are what define the limits.

Mechanical

Tensile strength, min
517 MPa
Yield strength (0.2%), min
205 MPa
Elongation, min
30 %
Condition
Annealed

Standards by form

Governing standard for each product form
Plate, sheet & strip ASTM B409
Pipe & tube ASTM B407
Bar & rod ASTM B408

Where it is specified

  • Process piping and heat exchangers to roughly 600 °C
  • Resists oxidation, carburisation and chloride stress-corrosion cracking
  • Where sustained creep service is required, specify 800H or 800HT

The risk runs backwards: 800 sold against an 800H requirement

The risk on 800 runs the other way to 800H: buyers are sometimes sold 800 against an 800H requirement. If the application involves sustained high temperature, the grade designation on the order is the thing to check first.

What we specify and check

  • Confirmation that 800, not 800H, is what the application actually requires
  • PMI for Ni and Cr against B409
  • Certificate matched to the delivered heat

We commission an accredited independent laboratory to test the heat before the material leaves China. You will receive that report unedited, whether it passes or not.

Request Incoloy 800

Tell us the form, dimensions and service conditions. We reply with availability, indicative landed price, lead time and the test regime we would specify for your application.